{"id":36519,"date":"2015-08-25T13:46:20","date_gmt":"2015-08-25T10:46:20","guid":{"rendered":"http:\/\/eurothermgroup.com.ua\/?page_id=36519"},"modified":"2025-09-03T05:52:45","modified_gmt":"2025-09-03T05:52:45","slug":"dimohodnie-gazovie-kotly-eurotherm-kt","status":"publish","type":"page","link":"https:\/\/eurothermgroup.com.ua\/en\/gazovie-kotli-otopleniya\/bitovie-gazovie-kotli\/dimohodnie-gazovie-kotly-eurotherm-kt\/","title":{"rendered":"Eurotherm KT TS\/TB chimney gas boilers +"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-12ca2eb4 wp-block-columns-is-layout-flex\" style=\"padding-right:0px;padding-left:0px\">\n<div class=\"wp-block-column has-border-color has-ast-global-color-5-border-color is-layout-flow wp-block-column-is-layout-flow\" style=\"border-width:1px;padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--30);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--30);flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/Untitled-1-copy2-1.jpg\" alt=\"\" class=\"wp-image-39620\" srcset=\"https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/Untitled-1-copy2-1.jpg 600w, https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/Untitled-1-copy2-1-300x300.jpg 300w, https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/Untitled-1-copy2-1-150x150.jpg 150w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\"><a href=\"\/wp-content\/uploads\/sites\/2\/rukovodstvo%20dimohodnie.pdf\">\u0406\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0456\u044f \u0437 \u0435\u043a\u0441\u043f\u0443\u0430\u0442\u0430\u0446\u0456\u0457<\/a><\/p>\n\n\n\n<p class=\"has-text-align-center\"><strong>\u041e\u0442\u0440\u0438\u043c\u0430\u0442\u0438 \u043a\u043e\u043d\u0441\u0443\u043b\u044c\u0442\u0430\u0446\u0456\u044e, \u0437\u0430\u043c\u043e\u0432\u0438\u0442\u0438:<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-a89b3969 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button popup-btn\"><a class=\"wp-block-button__link has-background wp-element-button\" style=\"background-color:#d4000b\">\u0417\u0430\u043c\u043e\u0432\u0438\u0442\u0438<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>KT TS(P2) and KT TV(P2) devices are intended for heat supply of individual houses, apartments and constructions of household appointment supplied with natural or artificial circulation water heating systems of the heat carrier with the working pressure of water up to 0,2 MPa (2 bars) and the maximum water temperature at the exit from a copper to 900C.<\/p>\n\n\n\n<p>Household heating gas devices with KT TS(P2) steel heat recovery system\u00a0are intended for water heating in water heating systems only.\u00a0KT TV(P2) with the steel heat double-circuit recovery system devices\u00a0are intended water heating in water heating systems and water heating for hot water supply (with copper heat recovery system\u2019s bypass duct). By placing main body\u2019s special design copper exchanger into water cavity it is possible to produce hot water for household needs. Copper heat recovery system\u2019s thermal capacity does not exceed the unit\u2019s nominal heat output.<\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>TECHNICAL SPECIFICATIONS OF BOILER<\/strong><\/h2>\n\n\n\n<p><strong>KT TS\/TB(P2) V,G \u00abSTANDARD\u00bb<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image alignwide size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"872\" height=\"1004\" src=\"https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-standart.jpg\" alt=\"\" class=\"wp-image-39923\" srcset=\"https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-standart.jpg 872w, https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-standart-261x300.jpg 261w, https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-standart-768x884.jpg 768w\" sizes=\"auto, (max-width: 872px) 100vw, 872px\" \/><\/figure>\n\n\n\n<div style=\"height:60px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>KT TS\/TB(P2) A,B \u00abLUX\u00bb<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image alignwide size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"871\" height=\"1010\" src=\"https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-lux.jpg\" alt=\"\" class=\"wp-image-39926\" srcset=\"https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-lux.jpg 871w, https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-lux-259x300.jpg 259w, https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-lux-768x891.jpg 768w\" sizes=\"auto, (max-width: 871px) 100vw, 871px\" \/><\/figure>\n\n\n\n<p><strong>KT TS\/TB(P2) L,M \u00abSTANDARD\u00bb<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image alignwide size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"870\" height=\"1012\" src=\"https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-standart-2.jpg\" alt=\"\" class=\"wp-image-39928\" srcset=\"https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-standart-2.jpg 870w, https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-standart-2-258x300.jpg 258w, https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-standart-2-768x893.jpg 768w\" sizes=\"auto, (max-width: 870px) 100vw, 870px\" \/><\/figure>\n\n\n\n<p><strong>KT TS\/TB(P2) \u041a \u00abLUX\u00bb<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image alignwide size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"870\" height=\"1012\" src=\"https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-lux-2.jpg\" alt=\"\" class=\"wp-image-39929\" srcset=\"https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-lux-2.jpg 870w, https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-lux-2-258x300.jpg 258w, https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/09\/tex-har-ki-lux-2-768x893.jpg 768w\" sizes=\"auto, (max-width: 870px) 100vw, 870px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong><strong>COPPER\u2019S DESIGN AND FUNCTIONAL OPERATION<\/strong><\/strong><\/h2>\n\n\n\n<p><strong>Devices compile of such parts:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>heat recovery systems with furnace and combustion products\u2019 intake tank;<\/li>\n\n\n\n<li>gas-oil unit with autogenous automatic equipment;<\/li>\n\n\n\n<li>decorative case.<\/li>\n<\/ul>\n\n\n\n<p><strong>The main knots, parts and details the devices&nbsp;of KT 8 TS(P2), KT 10 TS(P2), KT 10 TB(P2), KT 12 TS(P2), KT 12 TB(P2), KT 16 TS(P2), KT 16 TB(P2)&nbsp;are presented to&nbsp;in figure 1.<\/strong><\/p>\n\n\n\n<p><strong>The KT20 TS(P2), KT 20 TB(P2) and KT30TS(P2) devices major components, parts and details are presented on&nbsp;figure 2<\/strong>.<\/p>\n\n\n\n<p>The device, executed in form box-type structure form, is intended for floor-level installation near the outer wall. All basic elements of the device are fixed in its single case which is structurally unites fire-tube&nbsp;<strong>the heat recovery system 1&nbsp;<\/strong>,&nbsp;<strong>furnace 2&nbsp;<\/strong>,&nbsp;<strong>combustion products\u2019 intake tank 3<\/strong>&nbsp;and&nbsp;<strong>gas fuel unit 4&nbsp;<\/strong>. The copper\u2019s heat recovery system represents sheet steel and pipes pieces welded construction which form two cavities which are not connected among themselves. There is water in one of them (heated medium), and moving combustion products (gas air environment) in the other. The heat recovery unit is manufactured so that there was large free space limited from the back and to each side, forming&nbsp;<strong>the furnace 2&nbsp;<\/strong>in its lower part. the bunch of heat recovery system tubes that connects furnace to the air-gas flow path\u2019s upper part \u2013&nbsp;<strong>the combustion products\u2019 intake tank 3&nbsp;<\/strong>is located over a furnace, in the upper part of which there is a special branch pipe for \u0441ombustion products\u2019 organized tapping into a chimney.<br><strong>The gas fuel unit 4&nbsp;<\/strong>represents metal&nbsp;<strong>plate 5 ( frontal leaf)&nbsp;<\/strong>with the side outer of which the gas&nbsp;<strong>spray header 7 is fixed&nbsp;<\/strong>, and the main&nbsp;<strong>burners 19 are placed&nbsp;<\/strong>on the inside against flow diffusers. The flame-igniter (pilot burner) 6 block is also attached to the frontal leaf , consisting of actually igniter, and thermocouple and thermogenerating room located on its both sides, and ignition biosencing electrode is also fixed over it. The frontal leaf is attached to heat recovery system in such a way that burners and working parts flame-igniter block are placed into furnace, and the spray header along with thermal couple lead and thermogenerating room, are out of furnace. The spray header gas delivery is made through gas pressure regulator&nbsp;<strong>(autogenous automatic equipment) 8&nbsp;<\/strong>with piezo-element fixed on it. The gas-pressure reducer is attached to the spray header and flame-igniter by pipelines. The heat recovery system with furnace is covered with effective metal-clad outside surface thermal insulation.<\/p>\n\n\n\n<p>The decoratory case of the device consists of two side 9 , front 10 and upper walls 11 . The gas fittings governing bodies are removed through the top wall of its front part. Access to governing bodies in KT 20 TS(P2), KT 20 TV(P2) and KT 30 TS(P2) devices is limited by decorative opening plastic cover 18 . The branch pipes 12 and 13 which can be located both on the back wall, as well as on sidewalls of the device, depending on its model are removed by for device connection to outer heating pipelines from its corresponding elements. The GVS edge\u2019s pipeline connection is piped behind through branch pipes 14, 15 . The combustion products formed in furnaces pass through heat recovery system consisting of several fire-tube 20 rows where stainless steel turbulizers 21 are placed for heat exchange intensification. The draft stabilizer 16 is located over the heat recovery system with the draft sensor 17 mounted on it. The draft stabilizer is intended for external meteorological factors (temperature, humidity, wind speed) per furnace draft intensity influence decrease.<strong>Devices compile of such parts:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>heat recovery systems with furnace and combustion products\u2019 intake tank;<\/li>\n\n\n\n<li>gas-oil unit with autogenous automatic equipment;<\/li>\n\n\n\n<li>decorative case.<\/li>\n<\/ul>\n\n\n\n<p><strong>The main knots, parts and details the devices&nbsp;of KT 8 TS(P2), KT 10 TS(P2), KT 10 TB(P2), KT 12 TS(P2), KT 12 TB(P2), KT 16 TS(P2), KT 16 TB(P2)&nbsp;are presented to&nbsp;in figure 1.<\/strong><\/p>\n\n\n\n<p><strong>The KT20 TS(P2), KT 20 TB(P2) and KT30TS(P2) devices major components, parts and details are presented on&nbsp;figure 2<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"950\" height=\"651\" src=\"https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/2.bmp\" alt=\"\" class=\"wp-image-39632\" srcset=\"https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/2.bmp 950w, https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/2-300x206.jpg 300w, https:\/\/eurothermgroup.com.ua\/en\/wp-content\/uploads\/sites\/2\/2025\/08\/2-768x526.jpg 768w\" sizes=\"auto, (max-width: 950px) 100vw, 950px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">DESIGN FEATURES<\/h2>\n\n\n\n<p>They use devices for burning air of the room in which they are established (have the open combustion chamber). The combustion products\u2019 withdrawal is conducted into a flue. The air intake smoke fumes expulsion is performed naturally \u2014 at the expense of density difference. Devices are supplied with draft stabilizers and have the combustion products withdrawal monitoring system. Thanks to the GVS built-in copper heat recovery unit the device provides water heating for domestic needs. The steel heat exchanger is executed from thick-walled boiler pipes with built-in turbulizers stainless steel that increases exploitation period of the device and long-term maintenance of its operational specifications. At the expense of heat exchanger\u2019s original design and burning air supply optimum organization, the devices functional operation is silent.<\/p>\n\n\n\n<p>The device\u2019s design provides:<br>\u2022 automatic maintenance of given heat carrier temperature;<br>\u2022 gas-feeding block signaling in case of short-term interruption in gas supply or in case of main or pilot burner\u2019s blackout;<br>\u2022 gas-feeding block signaling in case of combustion products\u2019 ingress to the room where the device is established;<br>\u2022 heating area where the device without radiator application is established.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u0406\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0456\u044f \u0437 \u0435\u043a\u0441\u043f\u0443\u0430\u0442\u0430\u0446\u0456\u0457 \u041e\u0442\u0440\u0438\u043c\u0430\u0442\u0438 \u043a\u043e\u043d\u0441\u0443\u043b\u044c\u0442\u0430\u0446\u0456\u044e, \u0437\u0430\u043c\u043e\u0432\u0438\u0442\u0438: KT TS(P2) and KT TV(P2) devices are intended for heat supply of individual houses, apartments and constructions of household appointment supplied with natural or artificial circulation water heating systems of the heat carrier with the working pressure of water up to 0,2 MPa (2 bars) and the maximum water [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":36833,"parent":36510,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-36519","page","type-page","status-publish","has-post-thumbnail","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false},"uagb_author_info":{"display_name":"tividev.online@gmail.com","author_link":"https:\/\/eurothermgroup.com.ua\/en\/author\/tividev-onlinegmail-com\/"},"uagb_comment_info":0,"uagb_excerpt":"\u0406\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0456\u044f \u0437 \u0435\u043a\u0441\u043f\u0443\u0430\u0442\u0430\u0446\u0456\u0457 \u041e\u0442\u0440\u0438\u043c\u0430\u0442\u0438 \u043a\u043e\u043d\u0441\u0443\u043b\u044c\u0442\u0430\u0446\u0456\u044e, \u0437\u0430\u043c\u043e\u0432\u0438\u0442\u0438: KT TS(P2) and KT TV(P2) devices are intended for heat supply of individual houses, apartments and constructions of household appointment supplied with natural or artificial circulation water heating systems of the heat carrier with the working pressure of water up to 0,2 MPa (2 bars) and the maximum water&hellip;","_links":{"self":[{"href":"https:\/\/eurothermgroup.com.ua\/en\/wp-json\/wp\/v2\/pages\/36519","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eurothermgroup.com.ua\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/eurothermgroup.com.ua\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/eurothermgroup.com.ua\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/eurothermgroup.com.ua\/en\/wp-json\/wp\/v2\/comments?post=36519"}],"version-history":[{"count":13,"href":"https:\/\/eurothermgroup.com.ua\/en\/wp-json\/wp\/v2\/pages\/36519\/revisions"}],"predecessor-version":[{"id":39931,"href":"https:\/\/eurothermgroup.com.ua\/en\/wp-json\/wp\/v2\/pages\/36519\/revisions\/39931"}],"up":[{"embeddable":true,"href":"https:\/\/eurothermgroup.com.ua\/en\/wp-json\/wp\/v2\/pages\/36510"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eurothermgroup.com.ua\/en\/wp-json\/"}],"wp:attachment":[{"href":"https:\/\/eurothermgroup.com.ua\/en\/wp-json\/wp\/v2\/media?parent=36519"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}